Recover Data on Failed NEC CLUSTERPRO/ExpressCluster SE Shared Disks
If the shared disk fails, but the cluster nodes are undamaged, perform the following steps to recover data residing on the shared disks:
To recover data residing on the shared disks
- On each cluster node, select Control Panel, Services, and change the Startup Type of the following services to Manual:
- NEC ExpressCluster Server
- NEC ExpressCluster Log Collector
- Shut down the cluster and turn off all servers.
- Turn off the shared disk and replace the shared disk if necessary.
- Turn on the shared disk, and set the parameters for the shared disk.
- If RAID reconstruction or LUN configuration change is necessary, use the setting tool attached with the shared disk. See the shared disk documentation for information about the setting tool.
- To perform any setting or configuration from a cluster node, turn on only one server at a time.
- On the primary cluster node only, perform the following procedure:
- Write a signature (identical to the original) to the disk with the operating system’s disk administrator, if one does not already exist.
- Recreate the original partitions on the disk. If X-Call settings have been performed to HBA, you must connect the partition using the NEC ExpressCluster disk administrator before formatting.
- Using the operating system’s disk administrator, specify the original drive letter to the shared disk.
- Use Arcserve Backup to restore the backed up data to the shared disk.
- If you have performed X-Call settings for a disk, start the NEC ExpressCluster disk administrator and specify the recovered shared disk as X-CALLDISK in X-CALL DISK configuration.
- If you have performed X-Call settings for HBA, these settings are not changed. Go on to the next step.
- If the disk access path has been dualized, confirm that the access path is dualized.
- Reboot the server.
- Confirm that the drive letter is identical to the one you set in the previous step using the operating system’s disk administrator.
- Check the cluster letters on the CLUSTER disk partition with the NEC ExpressCluster disk administrator. If the cluster letter does not appear, set it to the original letter.
- Shut down the cluster node.
Note: X-Call is a setting that enables viewing of the shared partition from both the active and passive sides. See the CLUSTERPRO/ExpressCluster products document for more information about the setting for X-Call.
- Perform the following steps on all cluster nodes:
- Boot up the cluster node.
- Using the operating system’s disk administrator, specify the original drive letter to the shared disk, if necessary.
- Set the Startup type of the following services from Manual to Automatic:
- NEC ExpressCluster Server
- NEC ExpressCluster Log Collector
- Shut down the server and shut down the cluster node.
- Start all cluster nodes and perform the Return to cluster(R) operation from the NEC ExpressCluster Manager. Recover all servers to Normal.