Error E8046
Failed to Initialize Mapping Table. Disabling shared device. [Device: device number library vendor description] [library serial number].
Module
Library
Reason:
The primary server is unavailable or Not Ready at this time. Failed to synchronize the shared library’s information from the primary server when this member server starts up.
Action:
- Stop the Tape Engine Service on this member server.
- Check the status of the Tape Engine on the primary server. If the Tape Engine of primary server is down, start it.
- Re-start the Tape Engine Service on this member server.